Overview
P-AVN devices support AES67 audio transport as part of their IPMX-compliant media networking implementation. Interoperability with Q-SYS Core platforms is currently supported through the ST 2110-30 Receiver/Transmitter module available within Q-SYS.
At this time, native AES67 interoperability using the standard Q-SYS AES67 implementation has not been validated. Successful interoperability has been achieved using the SMPTE ST 2110-30 audio stream workflow in Q-SYS.
Requirements
- P-AVN device configured for AES67 audio transmission and/or reception
- Q-SYS Core with:
- ST 2110-30 Receiver and/or Transmitter components deployed in the design
- Layer 2/3 network supporting:
- Multicast traffic
- PTP timing distribution
- Appropriate QoS settings for media traffic
Configuration Summary
1. Configure the P-AVN Device
- Enable AES67 streaming on the P-AVN device.
- Verify the device is synchronized to the network PTP domain.
- Note the generated SDP information or multicast stream parameters:
- Multicast IP address
- Port number
- Sample rate
- Channel count
- Codec (typically PCM)
2. Configure Q-SYS
- Open the Q-SYS Designer project.
- Add an ST 2110-30 Receiver component for audio received from the P-AVN device.
- Import the SDP file or manually configure the stream parameters to match the AES67 stream generated by the P-AVN device.
- Confirm the stream locks and audio is present within the Q-SYS design.
For audio transmission from Q-SYS to P-AVN:
- Add an ST 2110-30 Transmitter component.
- Configure:
- Sample rate to match the P-AVN receiver requirements.
- Channel count as required.
- PTP synchronization enabled.
- Export or provide the SDP information to configure the P-AVN receiver.
Timing Considerations
Both platforms must share a common PTP timing source. Loss of synchronization may result in:
- Audio dropouts
- Stream lock failures
- Increased latency or jitter
Verify that all devices are participating in the same PTP domain and that network infrastructure supports IEEE 1588 traffic.
Validation
Successful interoperability has been validated using:
- P-AVN AES67 streams
- Q-SYS ST 2110-30 Receiver and Transmitter components
- Common PTP timing source
- Matching sample rate and channel configuration
Known Limitation
Current Q-SYS interoperability with P-AVN devices requires the use of the ST 2110-30 module. Standard AES67 workflows within Q-SYS have not been validated for interoperability with P-AVN devices at this time.
In certain cases there's a firmware inconsistency between Q-SYS and our 1.4.2 firmware, please reach out to our support team to receive the Beta Release that contains the fix for this.
Troubleshooting
| Symptom | Possible Cause |
|---|---|
| No audio received | SDP parameters do not match stream configuration |
| Stream will not lock | PTP synchronization issue |
| Audio dropouts | Network congestion, QoS, or PTP instability |
| Stream visible but silent | Sample rate or channel mapping mismatch |
Additional Notes
Because P-AVN devices are IPMX-certified, they utilize standards-based AES67/ST 2110 audio transport. Using the Q-SYS ST 2110-30 module provides the most reliable interoperability path and aligns with the underlying transport standards used by both platforms.